Our expert staff is familiar with various military standards - MIL-PRF-19500, 38510, 38534, 38535 and more. We can perform environmental testing and conditioning as described in the  MIL-STD-883, 750, or 202 methods or per your drawings and/or instructions.


               Equipment       Mfr.                      Capabilities 

Centrifuge

TrioTech

X,Y.Z orientations - up to 30KG

Fine leak detector

Varian

helium - down to 10(-8) range

Gross leak tester

TrioTech

fluorocarbon - bubble test detector

PIND

B&W Engr



Temp cycle

Blue M

air to air    -75C to +200C

Life test chambers
w/large board inventory  dedicated Engineer

Wakefield Engr.

static & dynamic life test and burn-in
screen for various device   types and package styles



                        Test                                 
    883
 Method           
 
        750
     Method
           
   202
Method      
 
Moisture resistance    1004   1021    106
Steady state life    10051026, 1027    108
Intermittent life    1006       1036, 1037    108
Stabilization bake    1008   1032
Salt Atmosphere (corrosion)       1009   1041    101
Temperature cycling    1010   1051    107
Thermal shock    1011   1056    107
Hermetic Seal - fine & gross        1014   1071    112
Burn-in    10151038, 1039,
1040,1042 
Internal water vapor    1018   1018
Constant acceleration    2001   2006    212
Mechanical shock    2002   2016
Solderability    2003   2026    208
Lead integrity    2004   2036    211
Vibration, variable frequency    2007   2056    214
External visual    2009   2071
Internal visual (monolithic)    20102069,2070,2072,     
2073,2074
Bond strength - destructive    2011   2037
Radiography    2012   2076    209
Resistance to solvents    2015   1022    215
Physical dimensions    2016   2066
Internal visual - hybrids    2017
Die shear    2019   2017
PIND    2020   2052    217
Bond Pull - non-destructive    2023   2037
Adhesion of lead finish    2025

PLEASE NOTE: Although we can perform the environmental testing procedures as described in the appropriate MIL-STD methods listed above, we are NOT currently on the DESC list of certified laboratories (but we are working on it).